GTek offers three different DC pump technologies to meet the various requirements of the OEM customer: Diaphragm, Linear-Motor Free Piston, and traditional Cup Seal. Each technology offers different operating characteristics and performance. Please consult your GTek representative to discuss the technology most suitable for your application. Typical lead time is 2-4 weeks, but varies based on demand.

Unit of Measure
Items
12 Volt (V) Direct Current (DC) Rated Voltage and 7.25 Pound Per Square Inch Gauge (psig) Maximum Pressure Linear Piston Direct Current (DC) Air Compressor

Air Compressor, Linear Free Piston, 5 LPM, 7.25 PSI, 12VDC, HD Feet
List Price QUOTE

12 Volt (V) Direct Current (DC) Rated Voltage and 7.25 Pound Per Square Inch Gauge (psig) Maximum Pressure Linear Piston Direct Current (DC) Air Compressor

Air Compressor, Linear Free Piston, 5 LPM, 7.25 PSI, 24VDC, HD Feet
List Price QUOTE

12 Volt (V) Direct Current (DC) Rated Voltage and 11.6 Pound Per Square Inch Gauge (psig) Maximum Pressure Linear Piston Direct Current (DC) Air Compressor

Air Compressor, Linear Free Piston, 2.5 LPM, 11.6 PSI, 12VDC, HD Feet
List Price QUOTE

12 Volt (V) Direct Current (DC) Rated Voltage and 11.6 Pound Per Square Inch Gauge (psig) Maximum Pressure Linear Piston Direct Current (DC) Air Compressor

Air Compressor, Linear Free Piston, 2.5 LPM, 11.6 PSI, 24VDC, HD Feet
List Price QUOTE

12 Volt (V) Direct Current (DC) Rated Voltage and 17.4 Pound Per Square Inch Gauge (psig) Maximum Pressure Linear Piston Direct Current (DC) Air Compressor

Air Compressor, Linear Free Piston, 1.0 LPM, 17.4 PSI, 12VDC, HD Feet
List Price QUOTE
Brands N/A GTek Automation
Direct Current (DC) Rated Voltage N/A 12 V N/A 24 V N/A 12 V N/A 24 V N/A 12 V
Direct Current (DC) Voltage Range N/A
Current N/A
Power N/A
Noise per 30 Centimeter (cm) N/A
Noise per 1 Meter N/A
Maximum Pressure N/A 50 kPa0.5 kgf/cm²0.5 bar7.25 psig N/A 50 kPa0.5 kgf/cm²0.5 bar7.25 psig N/A 80 kPa0.8 kgf/cm²0.8 bar11.6 psig N/A 80 kPa0.8 kgf/cm²0.8 bar11.6 psig N/A 120 kPa1.2 kgf/cm²1.2 bar17.4 psig
Open Flow Air Output N/A
Maximum Vacuum Pressure N/A
Outlet Outside Diameter (OD) N/A
Hose Barb Outlet Outside Diameter (OD) N/A 6 mm N/A 6 mm N/A 6 mm N/A 6 mm N/A 4.7 mm
Length N/A 3.00 in76 mm
Height N/A
Width N/A 2-3/4 in70 mm
Weight per Each N/A
Motor Type N/A
Connection Type N/A
Driver Type N/A
Thread Size N/A
Thread Type N/A
Box Length N/A 12 in
Box Width N/A 9 in
Box Height N/A 9 in
Pressure Rating N/A 20 kPa0.2 kgf/cm²0.2 bar2.9 psig N/A 20 kPa0.2 kgf/cm²0.2 bar2.9 psig N/A 50 kPa0.5 kgf/cm²0.5 bar7.25 psig N/A 50 kPa0.5 kgf/cm²0.5 bar7.25 psig N/A 100 kPa1.0 kgf/cm²1.0 bar14.5 psig
Rated Airflow1 N/A 5 L/min0.177 ft³/min N/A 5 L/min0.177 ft³/min N/A 2.5 L/min0.088 ft³/min N/A 2.5 L/min0.088 ft³/min N/A 1.0 L/min0.035 ft³/min
Current (Mean Value) N/A 0.81 A N/A 0.40 A N/A 0.74 A N/A 0.35 A N/A 0.74 A
Life Expectancy Mean Time to Failure (MTTF) N/A 10,000 h N/A 10,000 h N/A 10,000 h N/A 10,000 h N/A 5,000 h
Duty Cycle N/A Continuous
Coil Insulation Class N/A A or its equivalent
Gross Weight N/A 2.01 lb0.91 kg
Leadwire Length N/A 11-13/16 in300 mm
Measure System N/A EURO SI U.S.A
Ambient Temperature N/A 0 to 40 ºC
Ambient Humidity N/A 30 to 85 %
Fluid N/A Air
Attainable Vacuum N/A
Free Air Displacement N/A
Maximum Current N/A
Rated Operating Time N/A
Life Expectancy N/A
Pulse Width Modulation Control Voltage N/A
Pulse Width Modulation Control Frequency N/A
Pulse Width Modulation Control Duty Cycle N/A
Straight Nipple Inlet and Outlet Outside Diameter (OD) N/A
Hose Nipple Inlet and Outlet Outside Diameter (OD) N/A
Working Pressure Range N/A
Plate Thickness (t) N/A
Hole Diameter N/A
Hole Diameter Tolerance (±) N/A
Note for Mounting Dimension of Rubber Foot N/A
Applications N/A Analyzers Medical Equipment
Note N/A Heavy-duty rubber feet available on request. To prevent drop damage when located within portable devices.

Please read the page of "How to Use This Catalog" first for correct use of compressors and pumps.
  • 1 Air displacement at rated pressure.